Page 994 - CRESTRON HOME OS-3
P. 994

Setup

               Setup is different based on the model of the system.
               VISTA-15P, VISTA-15PSIA, VISTA-20P, VISTA-20PSIA, VISTA-21iP, VISTA-21iPSIA

               NOTE: Do not include leading zeros (0) when entering values.


                   1.  Enter [Installer Code]+800 to enter Programming mode. For example, if the Installer Code
                     is 1234, enter 1234+800.
                   2.  Press #91 to view the settings in the Options Selection menu. The Options Selection menu
                     displays [Options] and [Call-Waiting] values. Write down the Options value that is
                     displayed. This number will be entered in the following step.
                   3.  Press *91 to change the Options Selection settings. Enter [Options]+[Call-Waiting] to
                     assign the option and call waiting values.
                          l Options: Enter the Options value that was written down in the previous step.
                          l Call Waiting: To enable call waiting, enter 2. To disable call waiting, enter 3.

                           NOTE: The call waiting selection will only have an effect on systems with an SIA in
                           the model number, but it must still be entered on all systems.

                   4.  Press #190 to view the settings in the Keypad 2 Device Address 17 menu. The Keypad 2
                     Device Address menu displays the [Partition-Number] and [Sound] values. Write down the
                     Partition Number value that is displayed. This number will be entered in the following step.
                   5.  Press *190 to change the Keypad 2 Device Address 17 settings. Enter 5+[Sound] to set the
                     Partition Number to Partition 1 for Remote Services Sound to the value written down in
                     the previous step.
                   6.  Press #189 to view the settings in the Touch Screen Device (AUI) Enable menu. The Touch
                     Screen Device (AUI) Enable menu displays [AUI 1], [AUI 2], [AUI 3], and [AUI 4] values. Write
                     down the AUI 2, AUI 3, and AUI 4 values that are displayed. These numbers will be entered
                     in the following step.
                   7.  Press *189 to change the Touch Screen Device (AUI) Enable settings. Enter 5+[AUI 2] + [AUI
                     3] + [AUI 4] to set AUI 1 to 5 and to set AUI2, AUI 3, and AUI 4 to the values that were
                     written down in the previous step.

                   8.  Press *99 to exit programming mode. After the system resets, it should be ready for use
                     with the Crestron Home system.

               VISTA-128BPT, VISTA-128BPTSIA, VISTA-32FBPT, VISTA-128FBPT, VISTA-
               250FBPT, FA1660CT, VISTA-250BPT

                   1.  Enter [Installer Code]+800 to enter Programming mode. For example, if the Installer Code
                     is 1234, enter 1234+800.
                   2.  Press #+93 to enter Menu Mode and then press 0 until DEVICE PROG? is displayed on the
                     screen.

                   3.  Press 1 to enter Device Programming mode and display the DEVICE ADDRESS screen.





                Product Manual — Doc. 8525Z                                             Crestron Home™ OS • 977
   989   990   991   992   993   994   995   996   997   998   999