Page 993 - CRESTRON HOME OS-3
P. 993
Honeywell Security System
The Honeywell security system must be configured to work with the Crestron Home system.
Setup is performed using a Vista keypad with Alpha display (such as the Vista 6160).
NOTE: The Honeywell 4232CBM module is required in order to use Crestron Home system with
a Honeywell Vista security system.
Models
The following models are supported:
l VISTA-128FBPT
l VISTA-128BPT
l VISTA-128BPTSIA
l VISTA-15P (Firmware 9.1 or higher required)
l VISTA-15PSIA (Firmware 9.1 or higher required)
l VISTA-20P (Firmware 9.1 or higher required)
l VISTA-20PSIA (Firmware 9.1 or higher required)
l VISTA-21iP (Firmware 3.13 or higher required)
l VISTA-21iPSIA (Firmware 3.13 or higher required)
l VISTA-250BPT (Firmware 10.3 or higher required)
l VISTA-250FBPT
NOTE: The systems listed above support keypad emulation. They do not support an area list for
systems that support areas, area control to arm or disarm the system (including storing the
password on the UI device), programming area arm or disarm events, and triggering area
commands from button or trigger events via scenes.
Wiring
The Honeywell 4232CBM interface card should be connected to the Crestron Home system as
shown below:
Crestron Home System Honeywell 4232CBM
GND GND
TX RX
RX TX