Page 996 - CRESTRON HOME OS-3
P. 996
Configuring Multiple Keypads
For systems with multiple keypads, do not assign keypad address 17 to any keypad. TheCrestron
Home system uses address 17 to communicate with the Honeywell system.
NOTES:
l The Crestron Home system communicates with the security system over address 1 and 17
for commercial installations and 5 and 6 for residential installations. Do not assign a
keypad to address 1 and 17 for commercial installations and 5 and 6 for residential
installations.
l Keypad address 16 is factory enabled and cannot be disabled. Reserve this address for
physical keypads.
Check Keypad Addresses
To view the keypad address and verify that a keypad address is enabled:
1. Enter [Installer Code]+800 to enter Programming mode. For example, if the Installer Code
is 1234, enter 1234+800.
2. Enter the #+[Keypad-Address-Code] for the Keypad Address that you want to check:
Keypad Address Code Keypad Address
190 17
191 18
192 19
193 20
194 21
195 22
196 23
3. They keypad displays the [Partition-Number] and [Sound] values. If the partition number is
01 or higher, the keypad address is enabled. If the partition number is 00, the keypad
address is disabled.
Change a Keypad Address
1. Enter [Installer Code]+800 to enter Programming mode. For example, if the installer code
is 1234, enter 1234+800.
Product Manual — Doc. 8525Z Crestron Home™ OS • 979