Page 1096 - Med Plaza and Cancer Center
P. 1096

4.2 Twist-Lock Replaceable, Barrel Assembly
                                                                                                 Chapter 4
                                        Figure 4-2.  Frontbody Barrel Assembly






































                       4. Ensure that the O-ring (C) and washer (D) are in place on the frontbody
                          assembly before installing the twist-lock replaceable barrel assembly.
                                                                                                                4
                       NOTE:
                       Once the twist-lock replaceable barrel assembly is installed, the flat portion of the
                       barrel assembly should be located in the bottom, 6:00 position.



                       5. Lock the barrel assembly by twisting it back to its original 6:00 position.

                       6. To ensure proper operation of the twist-lock replaceable barrel assembly,
                          perform the “Function Checks” on page 2–3.

























                DiamondCare® Recessed Wall Outlet and Electrical Accessories (MAN01-045)  Page 4-5
   1091   1092   1093   1094   1095   1096   1097   1098   1099   1100   1101