“Oil-Less” Scroll Medical Air


            Appendix A: Desiccant Dryer



            A.1  General Information                             Manual Mode
                                                                 When the dryer is in the “Manual” mode, the
            CAUTION:  This manual is designed to serve as        dryer will shift towers every 30 seconds. At normal
            the operation and maintenance guide for your         operating conditions, one tower is at system
            dryer, if equipped. The contents of this manual      pressure and the other tower is at 0 p.s.i. Any
            should be carefully read BEFORE attempting any       condition other than this is not normal and will
            phase of operation or maintenance. Failure to        cause a high dew point condition. During tower
            follow the operating and maintenance procedures      changeover, the online chamber will exhaust,
            of the instruction manual could result in personal   and the chamber that is regenerating (purging)
            injury or property damage.                           will come to line pressure. There is a fi ve second
                                                                 re-pressurization cycle. If the dryer is in the
            All information, specifi cations and illustrations    continuous purge cycle (Manual Mode), the dryer
            within this manual are those in eff ect at the time   will use 15% of the NFPA system capacity to purge
            of printing. The manufacturer reserves the right to   the dryer.
            change or make improvements without notice and
            without incurring any obligation to make changes     Automatic Mode
            or add improvements to products previously sold.     When the dryer is in the “Automatic” mode, the
                                                                 dew point monitor controls the dryer purge, and
            When requesting information, service, ordering of    purging depends on the dew point condition.
            spare parts, etc., please reference all information   When the dew point reading is above the setpoint
            supplied on the serial number plate located on       of -10ºC (14ºF), the dryer will function normally
            the side of the control panel.                       (one tower at system pressure, one tower at 0
                                                                 p.s.i.). When the dew point is below the setpoint
            To facilitate maintenance, recommended spare         of -10ºC (14ºF), the purge valve will close. In this
            parts for your specifi c dryer model are available.   condition both towers will be approximately 100
            Failure to maintain recommended spare parts          p.s.i. and the dryer will not shift towers until the
            and fi lter cartridges might result in expensive and   dew point is above -10ºC (14ºF).
            unnecessary downtime for which the manufacturer
            cannot be responsible. To request a quotation of,    A.1.2   Pre-fi lter
            or place an order for, recommended or emergency
            spare parts, please contact BeaconMedæs Service      As the fi rst line of defense against water
            at 1-888-4MEDGAS.                                    contaminants, a coalescing pre-fi lter with an
                                                                 automatic drain is installed.  The coalescing pre-
            A.1.1   Drying Cycles                                fi lter removes water aerosols from the gas stream
                                                                 before the gas enters the dryer.  Liquids collected
            This fully automatic, heatless type dryer alternately   by the assembly’s fi lter cartridge(s) fall to the
            cycles the compressed, process gas fl ow through      housing sump and are drained by a fl oat  drain.
            two desiccant charged towers where the entrained,    Installer should pipe these drain connections to a
            vaporous moisture content of the gas is adsorbed.    common drain point.
            One desiccant tower is always on-line in a drying
            cycle throughout normal dryer operation. The
            opposite, off -line tower is in a regeneration cycle
            for removal of the previously adsorbed moisture
            content or in a purge saving cycle at line pressure.