Page 131 - 2018_IFC
P. 131

INTERIOR FINISH, DECORATIVE MATERIALS AND FURNISHINGS



                     system installed in  accordance with  Section   805.3.2.2.2 Mass loss test. Newly introduced mat-
                     903.3.1.1.                                      tresses shall have a mass loss not exceeding 15 per-
              805.2.2.3 Identification. Mattresses shall bear the label  cent of the initial mass of the mattress where tested
              of an  approved agency, confirming compliance with     in accordance with the test in Annex A3 of ASTM
              the requirements of Sections 805.2.2.1 and 805.2.2.2.  F1085.
         805.3 Group I-3, detention and correction facilities. The  805.3.2.3 Identification. Mattresses shall bear the label
         requirements in Sections 805.3.1 through 805.3.2 shall apply  of an  approved agency, confirming compliance with
         to detention and correction facilities classified in Group I-3.  the requirements of Sections 805.3.2.1 and 805.3.2.2.
           805.3.1 Upholstered furniture. Newly introduced uphol-  805.4 Group R-2 college and university dormitories. The
           stered furniture shall meet  the requirements of  Sections  requirements of Sections 805.4.1 through  805.4.2.3  shall
           805.3.1.1 through 805.3.1.3                        apply to college and university dormitories classified in
                                                              Group R-2, including decks, porches and balconies.
              805.3.1.1  Ignition by cigarettes. Newly introduced
              upholstered furniture shall be shown to resist ignition  805.4.1 Upholstered furniture. Newly introduced uphol-
              by cigarettes as determined by tests conducted in accor-  stered furniture shall meet  the requirements of Sections
              dance with one of the following:                   805.4.1.1 through 805.4.1.3
                1. Mocked-up composites of the upholstered furni-  805.4.1.1 Ignition by cigarettes. Newly  introduced
                   ture shall have a char length not exceeding 1.5  upholstered furniture shall be shown to resist ignition
                   inches (38 mm) when tested in accordance with   by cigarettes as determined by tests conducted in accor-
                   NFPA 261.                                       dance with one of the following:
                2. The components of the upholstered furniture       1. Mocked-up composites of the upholstered furni-
                                                                                                              1
                   shall meet the requirements for Class I when         ture shall have a char length not exceeding 1 / 2
                   tested in accordance with NFPA 260.                  inches (38 mm) when tested in accordance with
                                                                        NFPA 261.
              805.3.1.2 Heat release rate. Newly introduced uphol-
              stered furniture shall have limited rates of heat release  2. The  components  of the upholstered furniture
              when tested in accordance with ASTM E1537, as fol-        shall meet the requirements for Class I when
              lows:                                                     tested in accordance with NFPA 260.
                1. The peak rate of heat release for the single uphol-  805.4.1.2 Heat release rate. Newly introduced uphol-
                   stered furniture item shall not exceed 80 kW.   stered furniture shall have limited rates of heat release
                2. The total heat released by the single upholstered  when tested in accordance with ASTM E1537 or Cali-
                   furniture item during the first 10 minutes of the  fornia Technical Bulletin 133, as follows:
                   test shall not exceed 25 MJ.                      1. The peak rate of heat release for the single uphol-
              805.3.1.3 Identification. Upholstered furniture shall     stered furniture item shall not exceed 80 kW.
              bear the label of an approved agency, confirming com-       Exception: Upholstered furniture in rooms or
              pliance with the requirements of Sections 805.3.1.1 and     spaces  protected by an  approved  automatic
              805.3.1.2.                                                  sprinkler system installed in accordance with
           805.3.2 Mattresses. Newly  introduced mattresses  shall        Section 903.3.1.1.
           meet the requirements of  Sections 805.3.2.1  through     2. The total heat released by the single upholstered
           805.3.2.3.                                                   furniture item during the first 10 minutes of the
              805.3.2.1  Ignition by cigarettes. Newly introduced       test shall not exceed 25 MJ.
              mattresses shall be shown to resist  ignition  by ciga-     Exception: Upholstered furniture in rooms or
              rettes as determined by tests conducted in accordance       spaces  protected by an  approved  automatic
              with DOC 16 CFR Part 1632 and shall have a char             sprinkler system installed in accordance with
              length not exceeding 2 inches (51 mm).                      Section 903.3.1.1.
              805.3.2.2 Fire  performance tests. Newly introduced  805.4.1.3 Identification. Upholstered furniture shall
              mattresses shall be tested in accordance with Section  bear the label of an approved agency, confirming com-
              805.3.2.2.1 or 805.3.2.2.2.                          pliance with the requirements of Sections 805.4.1.1 and
                805.3.2.2.1 Heat release rate. Newly  introduced   805.4.1.2.
                mattresses shall have limited  rates of heat  release  805.4.2 Mattresses.  Newly introduced mattresses  shall
                when tested in accordance with ASTM  E1590  or   meet the  requirements of Sections 805.4.2.1 through
                California Technical Bulletin 129, as follows:   805.4.2.3.
                   1. The  peak  rate of heat  release for the  single  805.4.2.1 Ignition by cigarettes. Newly  introduced
                     mattress shall not exceed 100 kW.             mattresses shall be shown to  resist ignition  by  ciga-
                   2. The total heat released by the single mattress  rettes as determined by tests conducted in accordance
                     during the first 10 minutes of the test shall not  with DOC 16 CFR Part 1632 and shall have a char
                     exceed 25 MJ.                                 length not exceeding 2 inches (51 mm).



         98                                                                         2018 INTERNATIONAL FIRE CODE ®
  Copyrighted © 2017 by, or licensed to, ICC (ALL RIGHTS RESERVED); licensed to UL, LLC pursuant to License Agreement with ICC. No further reproductions authorized or distribution authorized.
  ANY UNAUTHROIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT; AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER.