FIRE AND SMOKE PROTECTION FEATURES


                                                  TABLE 721.1(3)—continued
                                     MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS a, q
                                                                             THICKNESS OF FLOOR   MINIMUM THICKNESS OF
                                                                               OR ROOF SLAB         CEILING
           FLOOR OR ROOF   ITEM              CEILING CONSTRUCTION                 (inches)           (inches)
           CONSTRUCTION  NUMBER
                                                                             4    3   2    1   4    3    2   1
                                                                            hours hours hours hour hours hours hours  hour
         17. Perlite concrete
         slab proportioned
         1:6 (Portland cement
         to perlite aggregate)   Perlite gypsum plaster on metal lath wire tied to  / " furring
                                                                   3
                                                                    4
         on a  / "-deep steel   17-1.1 channels attached with 0.065" (No. 16 B.W. gage) wire ties  —  2  p  2 p  —  —  7 / 8  3 / 4  —
             9
              16
         deck supported by      to lower chord of joists.
         steel joists 4 on
         center. Class A or B
         roof covering on top.
         18. Perlite concrete
         slab proportioned
         1:6 (Portland cement
         to perlite aggregate)
         on 1 / " -deep steel
             1
              4
         deck supported on
         individually
         protected steel
         framing. Maximum
         span of deck 6-10"
         where deck is less
         than 0.019" (No. 26   18-1.1 None                                   —   2 /  2 /  —   —    —   —    —
                                                                                 1 p
                                                                                      1 p
         carbon sheet steel                                                        4   4
         gage) and 8-0"
         where deck is 0.019"
         (No. 26 carbon sheet
         steel gage) or
         greater. Slab
         reinforced with
         0.042" (No. 19 B.W.
         gage) hexagonal
         wire mesh. Class A
         or B roof covering
         on top.
         19. Floor and beam
         construction
         consisting of 3" -     Suspended envelope ceiling of perlite gypsum plaster on
         deep cellular steel    metal lath attached to  / " cold-rolled channels, secured to
                                                3
         floor unit mounted     1 / " cold-rolled channels spaced 42" on center supported
                                                 4
                                 1
         on steel members   19-1.1  by 0.203 inch (No. 6 B.W. gage) wire 36" on center. Beams   2 p  —  —  —  1  l  —  —  —
                                  2
         with 1:4 (proportion   in envelope with 3" minimum airspace between beam soffit
         of Portland cement     and lath have a 4-hour rating.
         to perlite aggregate)
         perlite-concrete
         floor slab on top.
                                                        (continued)