Page 89 - Feed Lab
P. 89
Suguna Management System Ver 1.0 / SOP / FQL / P2 - 15 Page 1 of 2
15. Estimation of Pepsin Digestibility
SCOPE
To estimate the pepsin digestibility of protein for Animal
protein source materials.
APPARATUS
FAnalytical balance, 1 mg or 0.1 mg accuracy
(Picture - 1)
FFlat bottom flask with stopper (Picture - 2)
Picture - 3 Picture - 4
FIncubator (Picture - 3)
FFunnel (Picture - 4)
FKjeldhal Flask, 500 ml (Picture - 5)
FDigestion chamber (Picture - 6)
FConical flask, 250 ml, 150 ml (Picture - 7)
FVolumetric flask 1000 ml, 2000 ml (Picture - 8)
FBurette, 50 ml 0.02 tolerance (Picture - 9)
Picture - 5 Picture - 6
FHot air oven (Picture - 10)
Picture - 7 Picture - 8
Picture - 1 Picture - 2
Prepared by : Approved by :
77 Director - Technical