Page 3 - Microsoft Word - TECHNICAL SPECIFICATION- APOLLO HOSPITALS TEYNAMPET
P. 3
Document Name: TECHNICAL SPECIFICATION DOCUMENT NO.: ESCP-AUDOC-TESP-002
TECHNICAL SPECIFICATION.
Sl. No. Requirement Specification
1 Type of Parking Tower Parking (Front – Back Parking)
2 Types of Car Parked SUV Cars - 102 Cars
3 Mode of Construction Structural Construction
4 Area of Construction in metres 15.75 m Width x 23.35 m Length
(Length x Breadth)
5 Total Height of Structure 20 metres
(Excluding Head room)
6 Number of Lifts 3 Lifts
7 Number of Entries 3 Entries
8 Number of Exits 3 Exits
9 Number of Floors of Structure Ground + 6
10 Ground Level Height 4 metres
11 Other Floor Height 2.52 metres
12 Car Bay Size Length = 5.5 m
Width= 2.5 m
Height=2.52 m
13 Mode of Storing the cars Pallet less – Pin Type
14 Mode of operation Electrical + Hydraulic
15 Loading capacity per Parking Bay Up to 3000 Kg
16 Speed Details Lifting: Up to 50 m/min
Lateral : Up to 10 m/min
17 Motor Speed (RPM) 1440 RPM
2