Page 436 - Chief Architect Reference Manual
P. 436

Chief Architect X10 Reference Manual



                                                                • Select Unconditioned exclude the room
                           in the Preferences    dialog. See
                           “Architectural Panel” on page 121.     from the Conditioned Area, regardless of
                                                                  its Room Type.
                         2  Specify whether the selected room is   • Select Use Default for Room Type
                            included in the Living Area           (Conditioned/Unconditioned) to base
                        calculation. See “Living Area” on page 422.
                                                                  the selected room’s inclusion in the Liv-
                        • Select Include in Total Living Area Cal-  ing Area on its Room Type. The default
                           culation to include the room in the Living   for the selected Room Type is stated in
                           Area regardless of its Room Type.      parentheses.
                        • Select Exclude from Total Living Area     Options -
                           Calculation exclude the room from the   4
                           Living Area regardless of its Room Type.
                                                                • Specify the Roof Group of the selected
                        • Select Use Default for Room Type        room. Change this value to control how
                           (Included/Excluded) to base the selected   the program combines the selected room’s
                           room’s inclusion in the Living Area on its   roof system with that of the rest of the
                           Room Type. The default for the selected   building when automatic roofs are built.
                           Room Type is stated in parentheses.    This value is nearly always left at zero.

                         3  Specify whether the selected room is a   Not available in the Room Type Defaults
                            Conditioned Room or not. See          dialogs. See “Roof Groups” on page 777.
                        “Conditioned Area” on page 1281.        • Uncheck Include in Schedule to prevent
                        • Select Conditioned to include the room   the selected room(s) from being included
                           in the Conditioned Area of the structure,   in a Room Finish Schedule. See “Room
                           regardless of its Room Type.           Schedules” on page 444.

                                                     Structure Panel

                        Some settings on the STRUCTURE panel are   What appears in both the diagram and in the
                        also found in the Floor, Floor/Ceiling   settings to its left may be affected by the
                        Platform, and Room Type Defaults dialogs.   location where you clicked to select the
                                                                room. For example:
                        This panel features a cross section diagram
                        showing the relationships between its various   • If the selected room is located above two
                        heights and platform thicknesses. It is meant   rooms with different structural settings,
                        to represent the relationships between    the position of the pointer relative to these
                        heights and thicknesses rather than provide a   two lower rooms determines which of
                        scaled drawing of the model.              them displays as the floor below.
                        Two floors can be included in the diagram:   • If the selected room is located below two
                        the floor that the selected room is located on,   rooms with different floor heights, its
                        and the floor below it, if one exists.    absolute and relative ceiling height set-
                                                                  tings will be disabled.




                   436
   431   432   433   434   435   436   437   438   439   440   441