Page 40 - Airstream™ Series Dryer
P. 40

AIRSTREAM™ SERIES DRYER

             Electrical Diagram



             Pro Airstream™ Dryer Panel

                    Note:  High Voltage Primary Circuit 115VAC
                   Programmable Logic                           Motor Controller




                    To circuit breaker  To ground on terminal strip  To L2 on terminal strip  To 24VDC on PLC  To UP 1 entrance Photo Eye  To PE 2 Hold  To PE 3 exit Photo Eye  To PX 4 down Proximity Switch  To PX 5 up Proximity Switch  To PX 6 runaway Proximity Switch  To wiper on potentiometer (w)
                                                                To COMM on PLC  To Y 1 and Y 2 on PLC  To leg of potentiometer



                                                1 1  2 2  3 3  4 4  5 5  6 6  7 7  8 8  9 9  10 11 12
                                                               10 11 12 13 13
                    GND  S/S  X 1  X 3  X 5
                   L 1  L 2  X 0  X 2  X 4
                                                      F 1 input voltage fuse  L 1  L 2  M 1  M 2  F 1 ,motor fuse
                                                        20 Amp ABC fuse            4 Amp ABC fuse
                         IN  0  1  2  3  4  5
                           POWER
                           RUN
                                                                   To circuit breaker on terminal strip
                            PROG-E                                                  Down Potentiometer
                            CPU-E                                      To L 2 on terminal strip  To M+ on terminal strip  To M- on terminal strip
                         OUT 0  1  2  3                                                H      COMM2
                                                                                        To COM2 on PLC W
                     0 V  Y 0  Y 1  Y 2  Y 3
                  24VDC COM0  COM1 COM2 COM3                                               To pin #11 on motor controller  To pin #13 on motor controller

                                                         Terminal Strip
                   To 24VDC on terminal  strip and to S/S on PLC  To 0V on terminal strip  To pin #10 on motor controller  To pin #12 on motor controller  To leg of potentiometer  To pin #12 on motor controller  UP 1  PE 1  PE 2  PE 3  PX 4  PX 5  PX 6  Blank  24VDC  24VDC  0V  0V  M+  M-  L 2  Circuit Breaker  Ground






                                                  If dryer up function is to be used, remove the jumper
                                                  from UP 1 and Photo Eye 1. Run two wires from the
                                                  CCU to the dryer control panel. Hook one wire to the
                                                  common input and the remaining wire to the normally
                                                  open output.
                    Note:  Settings and LED review shown on the next page.