Page 126 - FreesStyler® Installation and Startup
P. 126

®
            INSTALLATION AND STARTUP


            Chapter 7 Treadle Assembly


            Connections

            The treadle has two electrical lines for proximity switches that require connection. Be sure that they
            are properly wired according to your site-specific drawings.
                   1)  Mount the Treadle Junction Box to the wall on the side of the Treadles Proximity Switches. Position the Junction Box at
                       least 6 feet from the floor to prevent unnecessary exposure to water and run conduit down the wall and over to the
                       Treadle.

                   2)  Feed the open end of the supplied cables up through the conduit and terminate in the Junction Box and to the SCC.




                                                                        Junction Box





                                                    Conduit
                                                                6 feet
                                                               minimum
                                                                        Electrical Terminations:
                                                                        Blue - 338
                                                                        Brown – 340
                                                                        Black – X11 (Entrance Proximity Switch)
                                                                        Black – X12 (Exit Proximity Switch)

                   3)  Connect the two Euro-Connectors to the Proximity Switches of the Treadle. Do Not mix  up  the  entrance  and  exit
                       connections.

                                                                 Euro-Connector

                                      Side View of Treadle (Floor Level)
                   Conduit to
                    Junction
                                                                                           Proximity Switch (typical)

























             7-6        Belanger, Inc. * 1001 Doheny Ct. * Northville, MI 48167 * Ph (248) 349-7010 * Fax (248) 380-9681       1MANUL220