Page 126 - FreesStyler® Installation and Startup
P. 126
®
INSTALLATION AND STARTUP
Chapter 7 Treadle Assembly
Connections
The treadle has two electrical lines for proximity switches that require connection. Be sure that they
are properly wired according to your site-specific drawings.
1) Mount the Treadle Junction Box to the wall on the side of the Treadles Proximity Switches. Position the Junction Box at
least 6 feet from the floor to prevent unnecessary exposure to water and run conduit down the wall and over to the
Treadle.
2) Feed the open end of the supplied cables up through the conduit and terminate in the Junction Box and to the SCC.
Junction Box
Conduit
6 feet
minimum
Electrical Terminations:
Blue - 338
Brown – 340
Black – X11 (Entrance Proximity Switch)
Black – X12 (Exit Proximity Switch)
3) Connect the two Euro-Connectors to the Proximity Switches of the Treadle. Do Not mix up the entrance and exit
connections.
Euro-Connector
Side View of Treadle (Floor Level)
Conduit to
Junction
Proximity Switch (typical)
7-6 Belanger, Inc. * 1001 Doheny Ct. * Northville, MI 48167 * Ph (248) 349-7010 * Fax (248) 380-9681 1MANUL220