                    Specifications

                    Requirements
                       Physical

                           Tunnel space: required driver side    58”
                           Tunnel space: required passenger side   58”
                       Utility
                           Electrical      Two 1 HP, 3-Phase Motors, terminated at Junction Box at base of Arm. See chart
                                           below for requirements.
                                           Two 24V Signal Wires from the configured LED SpinLite Lighting Panel, terminated
                                           at the supplied Junction Box at base of Arm
                                           Four 110V Control Wire, terminated at Supplied Pneumatic Control Panels
                           Water
                                           One 1/2” poly-flow tube for Chemical/Water, Tee’d to feed driver and passenger
                                           side, terminated at Utility Manifold

                           Pneumatic       Four 1/4” poly-flow tube Main Pneumatic feed to Air Panel (1CFM)
                                           Eight 1/4” Airlines for Extend and Retract of the Upper and Lower Cylinders on each
                                           SideWinder® Assembly, terminated at the Utility Manifolds

                       Electrical

                                Voltage           Hz            FLA
                                                              Per Motor

                                  208             60            1.85
                                  230             60            1.84
                                  480             60            0.92
                                  575             60            0.90




                                DISCONNECT AND LOCKOUT ELECTRICAL POWER BEFORE SERVICING ANY
                                                               EQUIPMENT!

                                                           CAUTION

                                     Always wear safety glasses when performing maintenance on any equipment.


                                                           CAUTION

                             It is recommended that a licensed electrician is contracted to perform all electrical installations.


                                                           CAUTION


                           A compressed Air System should be set correctly to support 90 PSI necessary to operate equipment,
                               but should never be set to deliver more than 120 PSI air pressure to the Belanger specified
                                                                 equipment.

                       1MANUL955       Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681      9