SideWinder
Specifications
Requirements
Physical
Tunnel space: required driver side 58”
Tunnel space: required passenger side 58”
Utility
Electrical Two 1 HP, 3-Phase Motors, terminated at Junction Box at base of Arm. See chart
below for requirements.
Two 24V Signal Wires from the configured LED SpinLite Lighting Panel, terminated
at the supplied Junction Box at base of Arm
Four 110V Control Wire, terminated at Supplied Pneumatic Control Panels
Water
One 1/2” poly-flow tube for Chemical/Water, Tee’d to feed driver and passenger
side, terminated at Utility Manifold
Pneumatic Four 1/4” poly-flow tube Main Pneumatic feed to Air Panel (1CFM)
Eight 1/4” Airlines for Extend and Retract of the Upper and Lower Cylinders on each
SideWinder® Assembly, terminated at the Utility Manifolds
Electrical
Voltage Hz FLA
Per Motor
208 60 1.85
230 60 1.84
480 60 0.92
575 60 0.90
DISCONNECT AND LOCKOUT ELECTRICAL POWER BEFORE SERVICING ANY
EQUIPMENT!
CAUTION
Always wear safety glasses when performing maintenance on any equipment.
CAUTION
It is recommended that a licensed electrician is contracted to perform all electrical installations.
CAUTION
A compressed Air System should be set correctly to support 90 PSI necessary to operate equipment,
but should never be set to deliver more than 120 PSI air pressure to the Belanger specified
equipment.