Page 35 - Kondor® KL 1 - E-1063 Programming and Operation Manual
P. 35
®
KL1: 1063 PROGRAMMING AND OPERATION
Chapter 4 Operator Interface/Advanced Configuration
Setup / Advanced Configuration
Screen Key
The following selections move you to the corresponding
screen:
· APPLICATION CONFIGURATION
· OUTPUT NAMING
The factory password for this level is 4444. This indicates security level 4.
ENABLED = ICS CLEAN CYCLE: This toggles between ENABLED and DISABLED. When ENABLED, a small
amount of water will evacuate chemical from the main orifices or Presoak Injectors when the machine is not in
use. Do not ENABLE this feature if the chemical pumps (SDM) are used instead of injectors (ICS).
Note: Output naming and application configuration must be modified to operate SDM
(Solution Discharge Module) instead of ICS (Injection Chemical System)
Chemical Delivery System, if applicable.