Page 35 - Kondor® KL 1 - E-1063 Programming and Operation Manual
P. 35

®
                      KL1: 1063 PROGRAMMING AND OPERATION


                      Chapter 4 Operator Interface/Advanced Configuration


                      Setup / Advanced Configuration

                                                                            Screen Key
                                                             The following selections move you to the corresponding
                                                             screen:
                                                              ·   APPLICATION CONFIGURATION
                                                              ·   OUTPUT NAMING








                           The factory password for this level is 4444. This indicates security level 4.
                             ENABLED = ICS CLEAN CYCLE: This toggles between ENABLED and DISABLED. When ENABLED, a small
                             amount of water will evacuate chemical from the main orifices or Presoak Injectors when the machine is not in
                             use. Do not ENABLE this feature if the chemical pumps (SDM) are used instead of injectors (ICS).
                                     Note:  Output naming and application configuration must be modified to operate SDM
                                            (Solution  Discharge  Module)  instead  of  ICS  (Injection  Chemical  System)
                                            Chemical Delivery System, if applicable.