Setup
SETUP / MISC
Setup / Misc / More
EMPTY BAY FLUSH: Toggles between DISABLED and ENABLED. When ENABLED, the system will
run one Thermo Cycle to flush the chemicals out of the Low Pressure System. The single Thermo
Cycle will occur after the machine has been “Not in Use” for 15 minutes. The Thermo Cycle P1 Output
must be selected if this feature is ENABLED.
EMPTY BAY PURGE TIME: This is the amount of time measured in seconds, that the machine will
use Purge Air to flush the manifolds when the system is “Not in Use”.
END CYCLE PURGE TIME: This is the amount of time measured in seconds that the machine will use
Purge Air to flush the manifolds immediately after the cycle is over. Typically used for the Saber®
system On-Board Dryer when the dryer turns on at the end of the cycle as the vehicle is leaving.
DO NOT PERFORM ANY MAINTENANCE ON THE MACHINE OR THE PUMP STATION
DURING AN EMPTY BAY FLUSH CYCLE UNLESS ALL POWER IS OFF.
3-12 Belanger, Inc.® * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681 1MANUL126