Page 29 - Kondor® KL 1 - E-1063 Programming and Operation Manual
P. 29
®
KL1: 1063 PROGRAMMING AND OPERATION
Chapter 3 Operator Interface/Programming
Setup
Setup / Misc
E-1063
PASSWORD RE-LOGIN LEVEL: The system allows for multiple levels of access. Each level requires a password.
Press the last word in the RE-LOGIN line (PASSWORD RE-LOGIN LEVEL NONE) to change the selection. Log-in
levels are shown above in the “Screen Key”. When a user presses the screen navigation keys, there will be an
automatic prompt to enter a password. Once the password is entered, access will be allowed for 5 minutes. If
more time is required, temporarily set the password Re-login level to NONE.
Example: If the Re-Login Level is 3 and a User has logged in at Level 3, the system would eventually time
out and restore access to Level 2. If the level is restored (reduced) to Level 2, then the User will be required
to enter a password to return to Level 3 access.
WEEP: This toggles between ON/OFF. ON enables the Weep function. MODE toggles between SCALED and
ON/OFF. For SCALED, the duty cycle is increased as the temperature decreases. When the system is in ON/OFF
mode, it is in constant WEEP for temperatures below 34° Fahrenheit.
TEMP SCALE: Here you can calibrate the Temperature Scale. A user can adjust temperature by + 9°/-15° of
what the sensor is reporting.
SONAR BACK ADDER: This is the number of inches after the Sonar reads the floor that will be considered
vehicle length.
SONAR FRONT ADDER: This is the number of inches before the Sonar reads the floor that will be considered
vehicle length.