Page 31 - Kondor® KL 1 - E-1063 Programming and Operation Manual
P. 31
®
KL1: 1063 PROGRAMMING AND OPERATION
Chapter 3 Operator Interface/Programming
Setup
SETUP / MISC
Setup / Misc / More
E-1063
CHANGE PASSWORD: Pressing this button will allow you to change the Passwords of all levels up to
the current level of access.
TIME AND DATE SETTINGS: The Time and Date fields are accessed by pressing the corresponding
buttons. Each button will move you to a screen where you will input the appropriate numbers for the
current time and date.
DISABLED E-STOP FAULT: Toggles between DISABLED and ENABLED. When ENABLED, the
system will page out when an E-Stop is pressed.
E-MAIL FAULTS: Toggles between DISABLED and ENABLED. When ENABLED, the system will e-
mail fault status when faulted.
Note: See Chapter 7 for the completion of set up for email faults.
PAGE FAULTS: Toggles between DISABLED and ENABLED. When ENABLED, the system will page
a fault status message using the phone line when the system is faulted.
E-MAIL DATA: Toggles between DISABLED and ENABLED. When ENABLED, the system will e-mail
limited accounting data at approximately midnight.
Note: See Chapter 7 for the completion of set up for email data.
THERMO-CYCLE DISABLED: This function should be set to DISABLED for most systems. Typically,
it is only used with cold climate systems that do not have doors. The Thermo-Cycle will run the Pump
at 15% through the High Pressure path for a user selectable time interval.
Note: Thermo-Cycle only occurs when the temperature falls below 34º Fahrenheit.
BETWEEN CYCLES: If the system is not in use, this is the time interval at which the Thermo-Cycle will
occur. For example: if it is set to 30 minutes, the Thermo-Cycle will occur every 30 minutes during
periods that the system is not in use and the temperature is below 34º Fahrenheit.
THERMO SECONDS: This is the run-time of the Thermo-Cycle. It will run the Pump at 15% through
the High Pressure path for the set amount of time.
DO NOT PERFORM ANY MAINTENANCE ON THE MACHINE OR THE PUMP STATION
DURING A THERMOCYCLE UNLESS ALL POWER IS OFF.
1MANUL126 Belanger, Inc. ®* PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681 3-11