                      Chapter 3 Operator Interface/Programming


                      Setup

                          SETUP / MISC

                          Setup / Misc / More
                                                   E-1063














                                     CHANGE PASSWORD: Pressing this button will allow you to change the Passwords of all levels up to
                                     the current level of access.

                                     TIME AND DATE SETTINGS: The Time and Date fields are accessed by pressing the corresponding
                                     buttons. Each button will move you to a screen where you will input the appropriate numbers for the
                                     current time and date.
                                     DISABLED  E-STOP  FAULT:  Toggles  between  DISABLED  and  ENABLED.  When  ENABLED,  the
                                     system will page out when an E-Stop is pressed.
                                     E-MAIL FAULTS: Toggles between DISABLED and ENABLED. When ENABLED, the system will e-
                                     mail fault status when faulted.
                                     Note:  See Chapter 7 for the completion of set up for email faults.

                                     PAGE FAULTS: Toggles between DISABLED and ENABLED. When ENABLED, the system will page
                                     a fault status message using the phone line when the system is faulted.
                                     E-MAIL DATA: Toggles between DISABLED and ENABLED. When ENABLED, the system will e-mail
                                     limited accounting data at approximately midnight.
                                     Note:  See Chapter 7 for the completion of set up for email data.

                                     THERMO-CYCLE DISABLED: This function should be set to DISABLED for most systems. Typically,
                                     it is only used with cold climate systems that do not have doors. The Thermo-Cycle will run the Pump
                                     at 15% through the High Pressure path for a user selectable time interval.

                                     Note:  Thermo-Cycle only occurs when the temperature falls below 34º Fahrenheit.
                                     BETWEEN CYCLES: If the system is not in use, this is the time interval at which the Thermo-Cycle will
                                     occur. For example: if it is set to 30 minutes, the Thermo-Cycle will occur every 30 minutes during
                                     periods that the system is not in use and the temperature is below 34º Fahrenheit.
                                     THERMO SECONDS: This is the run-time of the Thermo-Cycle. It will run the Pump at 15% through
                                     the High Pressure path for the set amount of time.




                              DO NOT PERFORM ANY MAINTENANCE ON THE MACHINE OR THE PUMP STATION
                                           DURING A THERMOCYCLE UNLESS ALL POWER IS OFF.