Page 59 - Chameleon® Arch Series
P. 59
CHAMELEON® ARCH SERIES
Installation
Leak Test / Nozzle Kit Installation (Applies only to the Spray Arch Option)
1) Electrically connect water solenoid valve or other optional equipment to the car wash controller unit (if
applicable).
2) Flush the system lines and manifolds.
3) Locate the selected nozzle kit and install the nozzles according to the nozzle configuration guide beginning
on the next page.
Note: Lubricate nozzles with liquid Teflon (NO TAPE) for easier installation and
maintenance.
4) Run water through the Arch and verify that there are no leaks at any of the fitting or nozzle locations.
Note: Nozzle selection is dependant on application, Nozzles vary for High-Pressure, Reclaim,
Pre-Soak, Waxes and R.O.
1MANUL526 Belanger, Inc. * 1001 Doheny Ct. * Northville, MI 48167 * Ph (810) 349-7010 * Fax (810) 380-9681 55