Page 37 - Low Side Washer
P. 37

LOW SIDE WASHER


                       Maintenance


                       Torque Plate and Electric Motor Replacement

                       The wiring to each motor will have to be removed in order  to  gain  access  to  the  bottom  of  the
                       gearbox. There you can inspect and change the flat head bolts used to mount the torque plate.

                          Remove Motor Gearbox assembly

                          1)  Turn off the power and place the disconnects  in the OFF position. To ensure safety we
                              recommend following the Lock out procedure stated above for the the main panel prior to
                              servicing the equipment.
                              If the assembly does not have a cover, proceed to step 3

                          2)  Remove  plastic cover from the cover base by removing the (2) Phillips head screws
                              mounted in to the cover base. This will allow access to the motor gearbox that is mounted
                              on the torque studs.











                          3)  To  ensure  all power has been properly removed from the circuit, check voltage at the
                              junction box with a multi-meter to confirm no power is being supplied to the equipment.
                          4)  Remove the junction box cover to gain access to the wiring on the side of the motor.
                          5)  Confirm that the wiring has been be tagged for terminal location if not previously identified
                              upon installation. Remove the nuts to release wiring from the terminal block.













                              Wires are located behind the terminal strip and will need to be pulled back out through the plastic fitting
                              at the bottom of the junction box.













                              This fitting will need to be loosened, or removed so that the wiring can be pulled down through the
                              cover base if equipped. Also, the terminal block may need to be removed from the side of the motor for
                              additional access using a Phillips screwdriver.

                       1MANUL858            Belanger, Inc. * 1001 Doheny Ct. * Northville, MI 48167 * Ph (248) 349-7010 * Fax (248) 380-9681        33