TIRE WASHER
Installation
Utilities
Pneumatic
1) Mount air regulation panel in the equipment room and route 1/4” poly-flow airlines to air panel as
shown below.
Tire Washer retract regulator
Passenger side regulator driver side / passenger side Manual over-ride
20 to 30 PSI
(1/4” airline)
Driver side regulator
20 to 30 PSI
Main air supply Retract Valve
90-PSI minimum
120-PSI maximum
2) Complete pneumatic circuit using 1/4” airline as shown below.
Extend
Extend
Driver side cylinder Passenger side cylinder
Retract
All lines shown are 1/4” poly-flo airline.
Electrical
1) Supply 110 VAC to the retract valve on air regulation panel from the carwash controller unit.
110 VAC in
CAUTION
It is recommended that a licensed electrician is contracted to perform all electrical installations.
All utilities MUST be installed in accordance with all local and national codes.
1MANUL738 Belanger, Inc. * 1001 Doheny Ct. * Northville, MI 48167 * Ph (248) 349-7010 * Fax (248) 380-9681 15