Page 41 - Saber® SL2 - E-1063 Programming and Operation Manual
P. 41

SL2: 1063 PROGRAMMING AND OPERATION


                       Chapter 4 Operator Interface/Advanced Configuration


                       Setup / Advanced Configuration

                           Advanced Configuration / Application Configuration

                       NAMED 1 - 8
                          NAMED         ON or OFF        ON             ON            OFF            WP
                                        YES / NO      FS / FE 000    FS / FE 000    FS / FE 000    YES / NO
                       Name of OUTPUT.   Toggles between   Toggles between FS and FE.   Toggles between   Toggles between
                       Typically renamed   YES and NO.   FS stands for “From Start”. FE stands for   FS and FE.   YES and NO.
                       to match the   If set to YES, the   “From End”.            FS stands for   If set to YES, the
                       application.   Output will function   The three zeros are the “Measured in   “From Start”. FE   Output will turn off
                                     with that      Inches”.                      stands for “From   during B/F
                                     application.                                 End”.         (Butterfly) in
                                                     Each NAMED 1 – 8 have two ON               motion to flush
                                                    positions.                    The three zeros
                                                                                  are the “Measured   pump.
                                                                                  in Inches”.
                                                                                  Each NAMED 1 –
                                                                                  8 have one OFF
                                                                                  position.
                                                                                  They all turn OFF
                                                                                  at the end of
                                                                                  application.

                       MISCELLANEOUS 1 - 7
                        MISC NAMED      ON or OFF        ON             OFF           PFFA           WP
                                        YES / NO      FS / FE 000    FS / FE 000    YES / NO       YES / NO
                       Name of OUTPUT.   Toggles between   Toggles between   Toggles between   Toggles between   Toggles between
                       Typically renamed   YES and NO.   FS and FE.   FS and FE.   YES and NO.   YES and NO.
                       to match the   If set to YES, the   FS stands for   FS stands for   PFFA stands for   If set to YES, the
                       application.   Output will function   “From Start”. FE   “From Start”. FE   “Position From   Output will turn off
                                     with that      stands for “From   stands for “From   Front Always”.   during B/F
                                     application.   End”.          End”.                        (Butterfly) in
                                                    The three zeros   The three zeros           motion to flush
                                                    are the “Measured   are the “Measured       pump.
                                                    in Inches”.    in Inches”.
                                                    Each MISC 1 – 7   Each MISC 1 - 7
                                                    have one ON    have one OFF
                                                    position.      position.























                        1MANUL294                  Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681                 4-3