Page 159 - Saber® Installation & Startup
P. 159

INSTALLATION & STARTUP


                      Chapter 10 Spot Free Rinse (RO)


                      Connections for Model 3000 GPD, Stand Mounted System
                             5)  Drill a 1-3/4“ hole centered 18” up from the floor. See drawings in Pur Clean manual. Install a float with rubber gasket to
                                 the inside of tank and replace nut. This float will plug into the control box for the re-pressurization pump.
                             6)  Drill 9/16” hole in top of tank and tap with a 3/8” pipe tap, thread in the plastic or brass fitting for the product tube. See
                                 drawings in Pur Clean manual.
                             7)  Locate 1/2” tube, if you have a brass fitting to tank, attach fitting to elbow in top of tank, if you have a plastic fitting, Insert
                                 into plastic elbow fitting on top of storage tank, other end attaches to the fitting behind the water quality light.
                             8)  Connect the 1-1/4“ hose from tank adapter to inlet of re-pressurization pump with the quick disconnect fitting.
                             9)  Make sure the reverse osmosis control unit switch is “OFF”. Now plug the reverse osmosis unit into the dedicated outlet.

                          RO Water Storage Tank

                                                                                Mount the product Water Inlet
                                                                                Connection 90° counter clockwise
                                                     Top View                   around from the Floats and Bulkhead
                                                                                Fittings

                                                                                    Mount the ON/OFF Float as close to
                                                                                    the top of the tank as possible
                                                                                    without interfering with the lid


                                                                                      Mount the Tank Overflow as
                                                    Front View                        close to the tanks shoulder
                                                                                      as possible
                                                                 100 Gallon
                                                                   Tank               Mount the Low Water
                                                                                      Bypass Float 18” up
                                                                                      from the floor

                                                                                      Mount the Bulkhead
                                                         18”                          Fitting 4” up from the
                                                                                      floor


                                                            4”
                          RO Installation Final Check List
                             ·   Is RO unit plugged IN?
                             ·   All hoses and fittings tightened?
                             ·   Is tap water valve turned ON?
                             ·   Is float plugged into controller?

                             Note:  See Chapter 25 (Initial Startup) before turning this unit on!

                             Note:  Refer to electrical schematics for connections.