Page 164 - Saber® Installation & Startup
P. 164
INSTALLATION & STARTUP
Chapter 11 Rocker Blaster and Rocker Spin Cleans
Rocker Blaster Utility Connections
1) Secure the check valve to the side manifold closest to the equipment room.
2) Position the manifold with the center hole 5” towards the driver side of the doorway’s centerline.
Centerline of Doorway
Direction
of Travel 23” 5” 44”
3) Make sure the holes of the main manifold are pointing directly upward and lag it to the floor.
CAUTION
Do not install nozzles or adjust angle of side manifolds until the system has been started and
flushed out.
4) The undercarriage manifold should be mounted to the floor with the 5° angle facing into the bay.
5º
Direction
of Travel
Side View, floor level
5) Run a single 3/4” water feed to the check valve.
Feed into
check valve
6) Rotate the Side Blaster Manifolds so they apply full side vehicle coverage.
Rotate one side to
cover the upper
portion of the vehicle
Rotate one side to
cover the lower
portion of the vehicle
11-2 Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681 1MANUL290