Page 51 - DuraTrans XD® Conveyor
P. 51

DURATRANS XD® CONVEYOR



                      Maintenance


                      Routine Procedures
                          Daily
                          ·   Verify proper chain tension.

                             Note:  The Tension Cylinder Assembly MUST NOT be at either extreme end of the cylinder
                                    stroke. Proper chain tension relies on free travel of the tension cylinders.
                             Note:  Due to natural wear of the chain, it will become necessary to remove chain link(s) in order
                                    to maintain proper tension.
                                                           CAUTION

                                     CAUTION: LOOSE CHAIN CAN CAUSE SERIOUS DAMAGE.
                          ·   Make sure that all Rollers are turning freely
                          ·   To prevent the possibility of damage to tires, visually inspect plastic Roller rollers for damage.

                          ·   Check overall performance for any abnormalities on the first few vehicles washed each day.
                          ·   To  keep  your  machine  clean,  nightly  wash  downs  are  recommended  (with  a  water  hose).
                              This should be done while conveyor is running
                          Weekly
                          ·   Inspect the idler sprocket slides for dirt build up and excess wear. Replace as required.
                          Monthly
                          ·   Inspect chain for wear.
                          ·   The manufacturer pre-fills the HECO gearbox with EPPCO GL-5 85W 140 gear oil. It should
                              be checked every month to be sure the proper amount of lubricant is maintained. To do this,
                              unscrew the setscrew located half way up the side of the gearbox. The oil level should be up
                              to this point (the set screw opening). If the level is lower, refill with EPPCO GL-5 85W 140 or
                              equivalent gear oil. See information on HECO Gear Reducer.
                          ·   The manufacturer pre-fills the electric drive gearbox with ISO 220 mineral oil. It should be
                              checked monthly to be sure the proper amount of lubricant is maintained. The oil should be
                              visible at the site-gauge (pointed out below). The lube should be changed every 10,000 hours
                              of service.

                                                                                 Breather Element for GW Gear-
                                     Breather Element for ISO 220 Oil            Lube (See HECO)










                                                               Site-Gauge
                                                                     Oil Level
                                                      Acceptable ISO 220 Mineral Oils
                                    AGIP    Blasia 220   Shell   Omala Oil 220   ESSO   Spartan EP220
                                    Mobil   Mobilgear 630   Castrol   Alpha Max 220   BP   Energol GR-XP 220



                      1MANUL010           Belanger, Inc.® * PO BOX 5470 *Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681     47