E-1063 PROGRAMMING AND OPERATION


            Chapter 4 Operator Interface/Programming


            Setup
                Setup / Misc
                                E-1063                   Screen Key
                                                  •  Access level 1: QUEUE
                                                  •  Access level 2: WASH DATA
                                                  •  Access level 3: SETUP
                                                  •  Access level 4: ADVANCED
                                                    CONFIGURATION





                   CHANGE PASSWORD: Pressing this button will allow you to change the Passwords of all levels up to the current
                   level of access.
                   PASSWORD RE-LOGIN LEVEL: The system allows for multiple levels of access that require a password for each
                   level. Press the last word in the RE-LOGIN line (PASSWORD RE-LOGIN LEVEL NONE) to change the selection.
                   Log-in levels are shown above in “Screen Key”. When  user presses the screen navigation keys, they  will
                   automatically be prompted to enter a password. Once password is entered access will be allowed for 5 minutes. If
                   more time is required, temporarily set password Re-login level to NONE.
                       Example: If Re-Login Level is 3 and User has logged in at Level 3, the system would eventually time out and
                       restore access to Level 2. Once level restored (reduced) to Level 2, the User will be required to enter a
                       password to return to Level 3 access.

                   TEMP SCALE: Here you can calibrate the Temperature Scale. User can adjust temperature by + 9°/-15° of what
                   the sensor is reporting.

                   DISABLED E-STOP FAULT: Toggles between DISABLED and ENABLED. When ENABLED system will page
                   out when an E-Stop is pressed.

                   E-MAIL FAULTS: Toggles between DISABLED and ENABLED. When ENABLED, system will e-mail fault status
                   when faulted.

                   E-MAIL DATA:  Toggles between  DISABLED and ENABLED.  When ENABLED, system will  e-mail  limited
                   accounting data at approximately midnight.

                   LOW WATER SHUTDOWN WASH: Toggles between LOW WATER SHUTDOWN WASH and LOW WATER
                   CONTINUE WASH. When in Shutdown Mode, system will fault, Page Out and will not wash vehicles until system
                   is reset.  When in Continue Mode, system will turn off Tire High-Pressure and continue wash. If water level is
                   restored for next vehicle system will attempt Tire High-Pressure again.
                   SONAR BACK ADDER: This is the number of inches after the Sonar reads the floor that will be considered
                   vehicle length.
                   X36 BACK ADDER: This is the number of inches after the entrance; Passenger Side Wheel IN reads “Switch ON”
                   that will be considered vehicle length.

                   Note:  This feature is only active if the entrance wheels ore ON for the first pass. This  is  not
                          recommended  because of an increased possibility of the Top Wheel going into the beds of pick-
                          up trucks.

                   TIME AND DATE SETTINGS: The Time and Date fields are accessed by pressing on the corresponding buttons.
                   Each button will move you a screen where you will input the appropriate numbers for the current time and date.





            4-12                 Belanger, Inc. * 1001 Doheny Ct. * Northville, MI 48167 * Ph (248) 349-7010 * Fax (248) 380-9681                    1MANUL224