               SETUP / MISC

                   SETUP / MISC / ECP (End Cycle Purge)
                                     E-1063                  Screen Key
                                                     •  Select the oval next to the
                                                       desired Outputs to have them
                                                       ON during the End Cycle Purge






                           PURGE TIME: Amount of time that the END CYCLE PURGE is ON in seconds.

                           DISABLED / ENABLED END CYCLE PURGE:  When enabled, END CYCLE PURGE will activate
                           after each wash cycle depending on temperature.

                           OPERATE BELOW 34 DEGREES / OPERATE EVERY WASH:  Toggles back-and forth between
                           these two fields to select if END CYCLE PURGE is temperature dependant.
                           When END CYCLE PURGE is ON, it will turn ON Outputs according to the selected ovals. It will also
                           turn ON the Purge valve. This feature will assist in operating in cold environments but is not a solution
                           (replacement) for bay doors and bay heat.