Page 42 - FreeStyler® E-1063 Programming and Operation Manual
P. 42
E-1063 PROGRAMMING AND OPERATION
Chapter 4 Operator Interface/Programming
Setup
SETUP / MISC
SETUP / MISC / ECP (End Cycle Purge)
E-1063 Screen Key
• Select the oval next to the
desired Outputs to have them
ON during the End Cycle Purge
PURGE TIME: Amount of time that the END CYCLE PURGE is ON in seconds.
DISABLED / ENABLED END CYCLE PURGE: When enabled, END CYCLE PURGE will activate
after each wash cycle depending on temperature.
OPERATE BELOW 34 DEGREES / OPERATE EVERY WASH: Toggles back-and forth between
these two fields to select if END CYCLE PURGE is temperature dependant.
When END CYCLE PURGE is ON, it will turn ON Outputs according to the selected ovals. It will also
turn ON the Purge valve. This feature will assist in operating in cold environments but is not a solution
(replacement) for bay doors and bay heat.
4-14 Belanger, Inc. * 1001 Doheny Ct. * Northville, MI 48167 * Ph (248) 349-7010 * Fax (248) 380-9681 1MANUL224