Installation
Double Manifold for UNIARCH
This configuration allows two Rain Arch manifolds to be mounted off of the Belanger Universal Arch on
the exit side. This allows the top nozzles of the Universal Arch to continue to be used.
U Bolt Clamp Spacer UNIARH Weldment
1) Notch the foam on both arms on the top side of the arch half way through from 11-5/8” to
18-1/8” from the end as shown below.
18-1/8” 18-1/8”
11-5/8” 11-5/8”
Fitting
Fitting
Note: Measurements on both foam sections are taken from the flat
outside surface of the fittings.