Page 21 - Rain Arch (all styles)
P. 21

RAIN ARCH MANUAL


                       Startup


                       Initial

                          1)  Confirm that all of the mall holes (fluid ports) in the manifolds are free of debris.
                          2)  Remove one end-cap from each manifold and flush with water to remove any debris. Replace the end-
                              caps.
                          3)  Confirm that the arch is delivering the desired amount of fluid using the example shown below.

                          How to determine GPM:
                           Note:  If you have a desire to control  flow rate beyond that of local water pressure, you should
                                  install some type of field-supplied ball-valve in-line to each manifold.

                              •   Use a channel of sorts to direct all fluids from a manifold to a 5 gallon bucket.
                              •   Turn on the system and allow the fluid to fill the bucket.

                              •   Record the time it takes to dispense 5 gallons and make adjustments at the ball-valve (whether
                                 field supplied or part of a Belanger SDM).
                                 Example: If it takes one minute to fill the 5 gallon bucket, the manifold is releasing 5 gallons per
                                 minute.



















































                        1MANUL650           Belanger, Inc. * 1001 Doheny Ct. * Northville, MI 48167 * Ph (248) 349-7010 * Fax (248) 380-9681        19