Page 20 - FreEsStyler® E-1032 Programming and Operation Manual
P. 20

E-1032 PROGRAMMING AND OPERATION


            Chapter 3 Operator Interface/Programming


            Setup


                Setup / Application Setup
                                    E-1032                                   Screen Key
                                                            •  Columns FILL, DWELL and PURGE are measured in
                                                              seconds
                                                            •  Values may be changes in increments of tenths of a second



                   Fill Time: Delays motion while application is filling.

                   Dwell Time: Delays starting the next pass to allow chemical to soak on the vehicle longer. Typically this is not
                   necessary. Typically the speed of the Return Pass determines the soak time of the chemical.

                   Purge Time: Delays starting the next pass while turning on Purge Air. Presoaks turn on Purge Air during B/F IN
                   MOTION. All others turn on Purge Air once B/F IN MOTION is complete.

                   Note:  Setting the Purge timer too large will unnecessarily add to Cycle Time.




















































            3-2                 Belanger, Inc. * 1001 Doheny Ct. * Northville, MI 48167 * Ph (248) 349-7010 * Fax (248) 380-9681                    1MANUL226