Setup
Setup / Misc / Sonar
E-1032
SONAR OFFSET: FLOOR DISTANCE must be set before editing this field. Here you can calibrate the Sonar
Height. User can adjust height by + or – of what Sonar is reporting. Typical procedure is to measure distance from
Sonar to floor. Insert that measured value into the FLOOR DISTANCE field and adjust SONAR OFFSET until
measured height equals FLOOR DISTANCE. This method is more precise when Exit Sonar is measured with the
Carriage by the Exit Limit and Enter Sonar is measured with the Carriage by the Enter Limit.
FLOOR DISTANCE: This is the actual distance between the Sonar and the floor.
WINDOW ABOVE FLOOR: This is the number of inches above the FLOOR DISTANCE that will be considered by
the system to be the floor (i.e. On the JOG screen, the SONAR AT FLOOR oval will be filled).
WINDOW BELOW FLOOR: This is the number of inches below the FLOOR DISTANCE that will be considered by
the system to be the floor (i.e. On the JOG screen, the SONAR AT FLOOR oval will be filled).
Note: Sonar measurement is considered at the floor when MEASURED HEIGHT is between the
(FLOOR DISTANCE – WINDOW ABOVE FLOOR) and (FLOOR DISTANCE + WINDOW BELOW
FLOOR). Example: If FLOOR DISTANCE = 119 and WONDOW ABOVE FLOOR = 9 and WINDOW
BELOW FLOOR = 9, any measurement between 110 (119 - 9) and 128 (119 + 9) will be consider
Sonar at Floor.
Setup / Misc / EPC
E-1032
Setup / Misc / More
E-1032
CHANGE PASSWORD: Pressing this function key will allow you to change the Passwords of all levels up to the
current level of access.
PAGE FAULTS: Toggles between DISABLED and ENABLED. When ENABLED, system will page Faults using
the phone line when the system is faulted.