Page 24 - FreEsStyler® E-1032 Programming and Operation Manual
P. 24

E-1032 PROGRAMMING AND OPERATION


            Chapter 3 Operator Interface/Programming


            Setup


                   Setup / Misc / Sonar
                                        E-1032







                   SONAR OFFSET: FLOOR DISTANCE must be set before editing this field. Here you can calibrate the Sonar
                   Height. User can adjust height by + or – of what Sonar is reporting. Typical procedure is to measure distance from
                   Sonar to floor. Insert that measured value into the FLOOR DISTANCE field and adjust SONAR OFFSET until
                   measured height equals FLOOR DISTANCE. This method is more precise when Exit Sonar is measured with the
                   Carriage by the Exit Limit and Enter Sonar is measured with the Carriage by the Enter Limit.

                   FLOOR DISTANCE: This is the actual distance between the Sonar and the floor.
                   WINDOW ABOVE FLOOR: This is the number of inches above the FLOOR DISTANCE that will be considered by
                   the system to be the floor (i.e. On the JOG screen, the SONAR AT FLOOR oval will be filled).
                   WINDOW BELOW FLOOR: This is the number of inches below the FLOOR DISTANCE that will be considered by
                   the system to be the floor (i.e. On the JOG screen, the SONAR AT FLOOR oval will be filled).
                   Note:  Sonar measurement is considered at the floor when MEASURED HEIGHT is between the
                          (FLOOR DISTANCE – WINDOW ABOVE FLOOR) and (FLOOR DISTANCE + WINDOW BELOW
                          FLOOR). Example: If FLOOR DISTANCE = 119 and WONDOW ABOVE FLOOR = 9 and WINDOW
                          BELOW FLOOR = 9, any measurement between 110 (119 - 9) and 128 (119 + 9) will be consider
                          Sonar at Floor.

                   Setup / Misc / EPC
                                        E-1032







                   Setup / Misc / More

                                        E-1032






                   CHANGE PASSWORD: Pressing this function key will allow you to change the Passwords of all levels up to the
                   current level of access.


                   PAGE FAULTS: Toggles between DISABLED and ENABLED. When ENABLED, system will page Faults using
                   the phone line when the system is faulted.