            Chapter 3 Operator Interface/Programming


            Setup


                Setup / More
                   Setup / More / Exit Operation
                                        E-1032                                 Screen Key
                                                                •  Values to the right of the YES/NO toggles are
                                                                  measured in seconds
                                                                •  Pressing the MORE key will navigate to Entrance
                                                                  Operation 2 and 3

                   Fields to the right of “Exit Operation” allows changing the name of the function.

                   ON and OFF Columns: There are two fields under these headings. The left columns are YES/NO toggles and the
                   right columns display values in seconds. Seconds values may be changed in increments of tenths of a second/
                   This system is equipped with 3 Exit Functions.
                   Each of these functions could utilize one, all or any combination of ON conditions. The ON condition that is met
                   first will turn on the functions output.
                   Each of these functions could utilize one, all or any combination of OFF conditions. The OFF condition that is met
                   first will turn off the functions output.
                   These functions will not operate on the vehicle unless toggled to YES in the Package Setup.
                   Wash End: This is when the wash has completed its last programmed path (Application). The machine will be
                   rapidly Homing as the exit features are turning on.
                   EFP (End Function Pulse): This is designed to turn on exit functions while wash  is  still  in  progress.  Each
                   package has a Pass Number and a position from completing that pass that it turns on its EFP.
                   Exit 1 Photo, Exit Door: These are all inputs that require a “light-operated” Photo-Eye (i.e. the input turns off
                   when the vehicle blocks the Photo-Eye beam). The ON condition for these is when the input turns off. The OFF
                   condition is when the input turns back on.

                   Max-Time: This is an OFF condition only. It’s a maximum time that a function will stay on once it turns on.






























            3-8                 Belanger, Inc. * 1001 Doheny Ct. * Northville, MI 48167 * Ph (248) 349-7010 * Fax (248) 380-9681                    1MANUL226