Setup / More / Door Control
E-1032 Screen Key
• Values to the right of the YES/NO toggles are
measured in seconds
Door Operation toggles back and forth as shown / ..
Door Operation must be in AUTO for On-Board Door Controls to open or close the doors.
Temp Control: Toggles back and forth from TEMP CONTROL ON / TEMP CONTROL OFF. If system is to
automatically control the doors with respect to temperature, make sure Temp Control is on.
When outside temperature is above EXIT UP TEMP (Fahrenheit) the exit door will open and stay open unless
after hours
When outside temperature is above ENTER UP TEMP (Fahrenheit) the entrance door will open and stay open
unless after hours.
When outside temperature falls below AIR LOCK TEMP setting, this system will allow only one door completely
open at a time. As vehicle leave the bay and the exit door begins to close, the AIR LOCK DELAY dictates the time
before the entrance door begins to open.
Time Control: Toggles back and forth from TIME CONTROL ON / TIME CONTROL OFF. If system is to
automatically control the doors with respect to time of day, make sure Time Control is on.
WASH OPEN and WASH CLOSED settings are in military time (hh:mm). When time of day is after WASH OPEN
and before WASH CLOSED system is considered in the state of “During hours”. When time of day is not between
WASH OPEN and WASH CLOSED the system is considered in the state of “After Hours”.
After WASH CLOSED time, the system will not switch to the state “After Hours” until system has been without a
vehicle in the Loader or Wash for the CLOSED DELAY number of seconds.
EXIT PLS and ENTER PLS: Both of these toggle between the following: EXIT PLS / EXIT MNT and ENTER
PLS / ENTER MNT. This is toggling between “Maintained” and “Pulsed”. When toggled to Pulsed, door outputs
will remain ON for times specified by DOWN TIME and UP TIME.
Note: Typically systems are set to Pulsed to keep manual door control buttons operational.
DOWN TIME (in seconds) should be set long enough for the door to completely close.
UP TIME (in seconds) should be set long enough for the door to completely Open.
Enter Door Photo Eye and Exit Door Photo Eye will always be included in door control when system is in AUTO.
The additional Enter Photo Eye and the additional Exit Photo Eye may be ENABLED to be included in Automatic
Door Control.