Page 31 - FreEsStyler® E-1032 Programming and Operation Manual
P. 31

E-1032 PROGRAMMING AND OPERATION


                       Chapter 3 Operator Interface/Programming


                       Setup


                           Setup / More / More / Exit Wheels
                                                  E-1032







                                MONITOR RETRACT: The oval toggles from filled to un-filled. When filled the system will Fault if the Arms are
                                being instructed to open and either of the Out-Position Read Sensors are not on.

                                ON POSITION IF TOP WHEEL ON: This is the amount of inches from the front of the vehicle that the Exit
                                Wheels will turn on and move in if the Top Wheel is on for that pass.
                                15 SPEED SHIFT SPEED: This is the speed that the Carriage will travel when SPEED SHIFT is active on the
                                back of the vehicle. Displayed in Hz. Value is relative. Smaller values produce slower speeds.

                                085 SPEED SHIFT START: As Carriage is moving forward, this is the position that the Carriage Speed will
                                begin to slow down while keeping the Exit Wheels on the front of the vehicle.

                                025 SPEED SHIFT END: This is the position that the Speed-Shift Speed will stop being used. This should be a
                                position that is small enough to ensure that the Exit Wheels are no longer in contact with the front of the vehicle
                                when the Carriage speeds back up.

                                VFD MOTOR CONTROL: (ENABLED/DISABLED) – When enabled system will run Exit Wheel ON/OFF and
                                RPM from VFD on network. If enabled without having VFD installed for Exit Wheel will cause DRIVE COM
                                FAULTS.

                                EXIT WHEEL RPM: This is wheel rotation speed if VFD motor controller enabled.































                       1MANUL226                     Belanger, Inc. * 1001 Doheny Ct. * Northville, MI 48167 * Ph (248) 349-7010 * Fax (248) 380-9681                    3-13