Page 49 - Gyro Wrap™ Signature ® Series
P. 49

GYRO WRAP™ Signature ® Series


                       Operational Performance and Controls


                       Understanding Air-Over-Oil
                          Swing Flow Controls
                              These  are  the  Flow  Controls connected to each Oil Reservoir. They control the hydraulic flow rate from the
                              cylinder. On each stand (leg assembly), there are two such controls. One is for controlling the rate of Swing
                              Retract and the other for controlling the rate of Swing Extend.
                              The orientation of the hydraulic Flow Controls is set so that peak pressures seen in operation are contained within
                              the Hydraulic Cylinder. When adjustments are being considered, the technician should be aware that the focus is
                              not at what rate to allow flow IN, but the rate to allow flow OUT of the Hydraulic Cylinder. See diagram below to
                              below to better understand.

                              Flow Control Valve: Turning the Flow Control knobs adjusts the “Controlled Flow” of oil
                              being discharged from the Hydraulic Cylinder into the Oil Reservoir.
                              This Flow Control Valve has a “Flow Direction” arrow engraved on its side that indicates
                              free flowing oil that passes through the internal check valve into the Reservoir at a rate
                              determined by the force of the user-set Controlled Flow.



                            Dotted Arrows Show:                            Dotted Arrows Show:
                            Swing Retract                                  Swing Extend



                                 Flow Control
                                                                                           Reservoir

                                                               Flow Control                       Reservoir






                                              Cylinder





                       Understanding Regulator Adjustments
                          1RGLTR175
                              This is the adjustable control of the penetration pressure seen on the car.  This control also affects the settings of
                              the swing flow controls due to their operation is in series with this air regulator (Small Regulator on the Air Panel).



















                        1MANUL248            Belanger, Inc. * 1001 Doheny Ct. * Northville, MI 48167 * Ph (248) 349-7010 * Fax (248) 380-9681        45