Page 44 - Gyro Wrap™ Signature ® Series
P. 44

GYRO WRAP™ Signature ® Series


             Installation


             Utilities: Pneumatic, Water and Electrical
                Water Manifold Installation

                The following image shows the installation of the water manifolds for a passenger side main water feed.
                    1)  Locate the following components.
                             Main water feed



                                                                Passenger
                                                   Clamps (7)   Side Arm
                        Connector Hose                          water feed                Driver Side
                                                                                           Arm water
                                                                                              feed
                                                                   Connector Hose

                    2)  Using the supplied clamps, secure the hoses to the barbed hose fittings as shown below.
                                      Clamp

                                                         Clamp
                                                                 Clamp
                                     29-5/8” Hose
                                                                                             Clamp



                                                                                32-3/4” Hose


                    3)  Position the Manifold Assembly into the crossbeam as shown below. The fittings facing downward
                       are to pass through the holes in the crossbeam and the unfilled holes In the filler strips.












                    4)  Using the supplied clamps, secure the hoses sticking out of the base of the arms to the downward
                       facing barbed hose fittings.
                    5)  Run a field supplied 1/2” water feed to the main feed, barbed hose fitting.
                    6)  Make sure all clamps have been tightened
                    7)  Once the water connections are made and everything is tightened, you can run the water through
                       the system to flush out the manifolds.














              40          Belanger, Inc. * 1001 Doheny Ct. * Northville, MI 48167 * Ph (248) 349-7010 * Fax (248) 380-9681           1MANUL248