Page 27 - Pivoting Wheel Stinger™ Mix and Match
P. 27

PIVOTING WHEEL STINGER Mix and Match


                       Maintenance


                       Routine Procedures

                          Triple and Single Pods
                           •   Check spray nozzles
                           •   Run a test wash to begin each business day
                           •   Inspect all air-lines making sure they are not making contact with sharp objects or in the path of vehicles

                       Trouble Shooting

                              Problem                 Cause                             Solution
                          No chemical       •   Clogged foot valve on suction line   •   Clean or replace foot valve

                                            •   Empty storage tank       •   Fill storage tank
                                            •   Chemical pump has lost prime   •   Prime chemical pump
                                            •   Solenoid valve not energized   •   Check for proper operating voltage
                          Pulsating or weak   •   Dirt in solenoid valve   •   Disassemble and clean solenoid valve
                          spray
                                            •   Kink in hose             •   Remove any kinks from hose
                                            •   Inadequate water pressure   •   Open water valve to fullest

                                            •   Blocked screen           •   Call Distributor for advice on installing booster pump
                                            •   Spray holes clogged      •   Remove from Pod and blow the screen to remove any
                                                                             film
                                            •   Loose or bad fittings
                                                                         •   Disable  the Pod and clean with thin wire and blow
                                            •   In-Line Check Valve for      through each port
                                                water/chemical facing wrong
                                                direction                •   Check all fittings on the complete system to assure
                                                                             that they are tight and do not leak
                                                                         •   Make sure the arrow on the Check  Valve  is  facing
                                                                             towards the black Feed-Block of the Pod
































                       1MANUL586             Belanger, Inc. * 1001 Doheny Ct. * Northville, MI 48167 * Ph (810) 349-7010 * Fax (810) 380-9681        25