Utilities
Locate the following items:
(2) Copper manifolds, one with a vertical water feed and one without
(1) Section of water hose
(3) Barbed hose fittings
(3) Hose clamps
Water Manifolds Assembly
CAUTION
It is recommended that a licensed plumber is contracted to perform all water installations.
1) Determine the side in which you would like to supply the unit with water.
2) Secure the manifolds to the clamps on the underside of the crossbeam as shown.
Overhead View
Clamp (typical) Crossbeam
Water feed
3) Locate the barbed hose fittings. Secure one to opening on the underside of each manifold. This is
how one manifold will be fed from the other.
4) Secure the other fitting to the end of the vertical manifold. This is the main water feed.
®
Note: Fittings require a water sealant. We recommend using Teflon tape, pipe dope or an
equivalent.
5) Locate the hose clamps and slide two of them onto the supplied 3/4” water hose. Use the water
hose to connect the two manifolds together and slide the hose clamps into position.
Barbed
hose fitting Hose Clamp
(typical) (typical)
Teflon ® tape
(typical)
6) Slide the third hose clamp onto the hose being used as a main water feed and secure the main
water feed hose to the vertical manifold. Slide the hose clamps into position.