Page 16 - UNIARCH
P. 16

UNIARCH



            Installation


            Tunnel Placement
            When placing a piece of equipment, tunnel depth will vary from site to  site.  Be  sure  to  allow  an
            adequate operating envelope
                   1)  Once UNIARCH is fully assembled, stand it up in the appropriate location and lag the driver side leg
                       to the floor.












                                                     Direction
                                                       of
                                                      Travel







                                        45”


                                                    Overhead View
                             Dimensions are taken from the outer equipment leg to the driver side edge of the inside guide rail
                   2)  Confirm that the legs are  evenly spaced at the top and bottom  and  the Arch is level in both
                       directions. Lag the other side to the floor.









                                        Be sure legs are spaced the same at top and bottom








                                        Be sure legs are spaced the same at top and bottom


                   Note:  Make sure that the UNIARCH is level. Check that there is an equal measurement from the
                          driver’s side to the passenger’s side at both the top and bottom of the UNIARCH legs.








             14        Belanger, Inc. * 1001 Doheny Ct. * Northville, MI 48167 * Ph (810) 349-7010 * Fax (248) 380-9681          1MANUL795