Page 46 - Top Wheel Signature® Series
P. 46

SignatureSignature   SeriesSeries
            TOP WHEEL SignatureSignature  ®      SeriesSeries

            Maintenance


            Torque Plate and Electric Motor Replacement

            The  wiring  to  each  motor  will  have  to  be  removed  in  order  to  gain  access  to  the  bottom  of  the
            gearbox. There you can inspect and change the flat head bolts used to mount the torque plate.

                                                 DANGER

                    DISCONNECT MAIN POWER SUPPLY PRIOR TO SERVICING
                                      OR MAINTAINING EQUIPMENT

                Remove Motor Gearbox assembly
                1)  Turn off the power and place the disconnects in the OFF position. To ensure safety we recommend following the
                   Lock out procedure stated above for the main panel prior to servicing the equipment.
                   If the assembly does not have a cover, proceed to step 3
                2)  Remove both Phillip head screws, to allow plastic cover to be removed from cover base.



                                                 Remove Phillip Head Screws






                3)  Verify power has been removed from circuit by checking voltage at the junction box with a multi-meter to confirm
                   no power is being supplied to the equipment.
                4)  Remove the junction box cover to gain access to motor wiring.
                5)  Remove the nuts to release wiring from the terminal block.














                6)  Verify wiring has been tagged for proper terminal connections if not previously identified at original installation.
















             42          Belanger, Inc. * 1001 Doheny Ct. * Northville, MI 48167 * Ph (248) 349-7010 * Fax (248) 380-9681           1MANUL752
   41   42   43   44   45   46   47   48   49   50   51