Page 26 - Foaming Pods
P. 26

FOAMING PODS


            Installation


            Preparing the UNIARCH

               In order to mount the Foaming Pods to a UNIARCH, the protective foam must be cut. The
               recommended location is shown below.

               Front View
                                                                                      3”





                                                                             3”

                                                                     Closeup of foam cut for mounting

                                                                             Helpful Hint
                                      85”                              Dimensions and placement are
                                                                    recommendations. Actual placement may
                                                                   vary per location and cusomer preference.
                                                                   Keep in mind that you will want to carefully
                                                                   plan where you would like to mount the pods
                                                                        BEFORE cutting the foam.
                                                  Floor

               Top View

                                                         103”
                                      This dimension varies with mounting location and rotation position of Pods




                                                     Helpful Hint
                          When mounting Pods to a UNIARCH, thay can be rotated on the Tube-Manifolds for
                                       even more flexibilty in positioning (shown below).







                                Pods can be rotated around the UNIARCH Tubes.    Pods can also
                                This can allow the foam to hit the vehicle sooner   be pivoted up
                                       and provide a better rinse.                and down.






                                                                           Helpful Hint
                                            Direction of Travel
                                                           Be sure to turn the pods so that they are facing the entrance
                                                           of the tunnel. This allows maximum foam application before
                                                                  making contact with the water/chemicals

                        Note:  The above image is shown with Triple Foaming Pods. The mounting procedure is
                                the same for Single Pods.



             24        Belanger, Inc. * 1001 Doheny Ct. * Northville, MI 48167 * Ph (810) 349-7010 * Fax (810) 380-9681          1MANUL770