Page 114 - FreeStyler® Maintenance Manual
P. 114
®
MAINTENANCE
Chapter 3 General Repairs
Spot Free (RO)
3000 GPD Stand Mounted RO System Utility Requirements
Requirements 23” 24” Top View
Water
1” (25.4 mm) water line with
Ball Valve, 20 GPM @ 30 36”
PSI (75.7 LPM @ 2.1 BAR)
for RO System
Drain
Electrical
Two, 220V, 20 Amp, single
phase circuits, each with its
own L6-20 locking
receptacle. Place this plug
60” (154.4 cm) up from the 72” Front View
floor on the right side of the 64”
RO unit.
100 Gallon
Tank
Re-pressurization Pump
The purpose of the Re-pressurization pump is to re-pressurize the water from the holding tank and deliver it to “Spot-
Free” rinse. See the illustration below.
Note: On a stand-mounted unit, the re-pressurization pump is already mounted on the frame.
Attach the provided 3/4” hose from the outlet of the pump to the manifold.
Note: On the pump control box is an open 1/2” flexible conduit connector containing a black
wire, a white wire and a red with black tracer wire.
From your controller, run wires from output 06 to the black and from 110V common to
the white.
Note: The red with black is intended for low water notification and is not currently in use.