Page 169 - FreeStyler® Maintenance Manual
P. 169

®
                       MAINTENANCE


                       Chapter 3 General Repairs


                       Water Softener


                          Solving the Problem

                          Salty Treated Water – Applies to the Softener ONLY
                                     Problem                    Reason                       Solution
                           1.  Restricted drain line       The drain is kinked or clogged      Clear any obstructions. Make sure
                                                                                        that the drain line flows smoothly
                                                                                        and unrestricted
                           2.  Low water pressure          The unit should not see water      Test the outlet pressure with the
                                                            pressure drop below 15 PSI on the   unit in backwash and one faucet at
                                                            outlet at any time. During the   high flow. Measure the pressure by
                                                            backwash portion of the     placing a gauge on the brine fitting.
                                                            regeneration cycle, it must hold at   Raise pressure if below 15 PSI
                                                            least 15 PSI or the brine may not
                                                            rinse out completely
                                                           The pre-filter cartridge is plugged      Replace pre-filter cartridge
                           3.  The backwash flow control is      Without enough backwash flow to      Clean the backwash flow control
                               plugged                      the drain, the unit cannot wash all
                                                            the salt from the media tanks
                           4.  The drain is extremely long or      Such drain runs can put back-     Locate a closer drain or use a
                               placed higher than 8 feet above   pressure on the unit and restrict   larger diameter drain line
                               the floor                    the drain flow. This causes the
                                                            same result as number 3 above
                           5.  The upper distributors are      Foreign material that finds its way      Clean upper distributors. Install a
                               plugged. (This does not apply   into the media tanks may be   pre-filter
                               to High Efficiency softeners)   collected around the upper
                                                            distributors during backwash,
                                                            clogging them
                           6.  Water level in the brine drum is      The brine valve is set wrong or      Verify the brine valve setting. Re-
                               too high                     non-conforming              place non-conforming brine valve