            Chapter 3 General Repairs


            Water Softener


               Solving the Problem

               Taste, Color and Odor – Applies to the Softener ONLY
                          Problem                     Reason                      Solution
                1.  Treated water has a salty taste      In high TDS (1000+) applications,      Inform the customer of the Kinetico
                                                 salt taste may be present due to   Drinking Water System
                                                 the ion exchange process or
                                                 sodium chloride in the raw water
                                                See the section entitled "Salty
                                                 Treated Water"
                2.  Treated water has a yellow tint      The raw water may have traces of      If tannins are present, use tannin
                                                 tannins present              softener
                                                See the section entitled "Iron
                                                 Bleed-Through"
                3.  Treated water has an odor (hot      The magnesium rod in hot water      Remove this rod from the hot water
                    water only)                  tanks can cause a reaction that   heater. An alternative rod may be
                                                 gives off an odor of rotten eggs   installed

               Leaks – Applies to the Softener ONLY
                          Problem                     Reason                      Solution
                1.  Water leaks from any of the      M.V. screws are not tightened      Depressurize the unit and tighten
                    assembly levels                                           the M.V. screws
                                                One of the seals between      Replace the non-conforming seal
                                                 assembly levels (L-1 through L-4)
                                                 is pinched or missing
                                                One of the screw holes is stripped      Replace the base
                                                 or cracked
                                                There is a crack on the seal area      Replace the level
                                                 near a screw hole
                2.  Water feed pressure is too high      No pressure regulator installed      Install pressure regulator
                    (125 PSI maximum)           The pressure regulator is broken      Replace pressure regulator
                3.  Water leaks at the main base      The base is not tightened properly      Tighten base
                    or remote base              The O-ring on the base is pinched      Replace base O-ring
                                                 or missing

























             3-108            Belanger, Inc.® * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681                 1MANUL222