Solving the Problem
Equipment Noise- Applies to the Softener ONLY
Problem Reason Solution
1. The unit makes a squealing The control disc is not flat on the Replace the control disc, balance
noise ceramic, causing the drain valve to piston spring and the balance
flutter piston O-ring. You may also want
to change the drain valves and
seals
2. The unit makes a gurgling, On new installations, there may be Run through an entire cycle to al-
hissing or bubbling sound some air trapped in the unit initially low the air to escape
Air is being drawn into the Identify air leaks in the plumbing
plumbing and fix them
The brine line and/or the brine Identify and replace the faulty
valve are not air checking part(s)
Unit Sticks in Cycles – Applies to the Softener ONLY
Problem Reason Solution
1. The unit sticks in regeneration The control disc is not flat on the Clean the regeneration flow path
or backwash cycle ceramic, causing the drain valve to
flutter
The regeneration drive pawl and/or Replace the regeneration drive
spring is weak or broken pawl
There is a damaged tooth on the Replace the control disc
control disc
The eccentric pinion is worn Replace the eccentric pinion (snap
fit)
On backwashing filters, low Increase inlet pressure or the
pressure or poor backwashing may frequency of the backwash, or the
cause a plugged bed unit may need re-bedding
2. The unit sticks in service cycle The regeneration start pawl is Replace or install regeneration
broken or missing start pawl
The control disc has a worn or Replace control disc
missing tooth