Page 173 - FreeStyler® Maintenance Manual
P. 173

®
                       MAINTENANCE


                       Chapter 3 General Repairs


                       Water Softener


                          Solving the Problem

                          Equipment Noise- Applies to the Softener ONLY
                                     Problem                    Reason                       Solution
                           1.  The unit makes a squealing      The control disc is not flat on the      Replace the control disc, balance
                               noise                        ceramic, causing the drain valve to   piston spring and the balance
                                                            flutter                     piston O-ring. You may also want
                                                                                        to change the drain valves and
                                                                                        seals
                           2.  The unit makes a gurgling,      On new installations, there may be      Run through an entire cycle to al-
                               hissing or bubbling sound    some air trapped in the unit initially   low the air to escape
                                                           Air is being drawn into the      Identify air leaks in the plumbing
                                                            plumbing                    and fix them
                                                           The brine line and/or the brine      Identify and replace the faulty
                                                            valve are not air checking   part(s)

                          Unit Sticks in Cycles – Applies to the Softener ONLY
                                     Problem                    Reason                       Solution

                           1.  The unit sticks in regeneration      The control disc is not flat on the      Clean the regeneration flow path
                               or backwash cycle            ceramic, causing the drain valve to
                                                            flutter
                                                           The regeneration drive pawl and/or      Replace the regeneration drive
                                                            spring is weak or broken    pawl
                                                           There is a damaged tooth on the      Replace the control disc
                                                            control disc
                                                           The eccentric pinion is worn      Replace the eccentric pinion (snap
                                                                                        fit)
                                                           On backwashing filters, low      Increase inlet pressure or the
                                                            pressure or poor backwashing may   frequency of the backwash, or the
                                                            cause a plugged bed         unit may need re-bedding
                           2.  The unit sticks in service cycle      The regeneration start pawl is      Replace or install regeneration
                                                            broken or missing           start pawl
                                                           The control disc has a worn or      Replace control disc
                                                            missing tooth

























                       1MANUL222               Belanger, Inc.® * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681                  3-109