Page 59 - FreeStyler® Maintenance Manual
P. 59
®
MAINTENANCE
Chapter 2 Preventative Maintenance
Pumping Station Float Valve Seal Replacement Kit #105884
Positioning the Float Valve for Operation
For optimum closing force and best operation of the Float Valve it is suggested that the Float Arm Assembly be set to a
45° or slightly greater angle. The Float Valve will not operate properly with the arm at a 90° angle.
Optimum
Working
Range
45°
When properly set, the Float valve should look as shown below
If the Down-Tube extends below the surface of the liquid, the Float Valve may become air bound and not close
properly. A small drilled hole (approximately 1/8”) has been drilled in the lower neck of the valve body, above the
thread to allow air to escape.
1/8” drilled hole
1MANUL222 Belanger, Inc.® * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681 2-31