Page 59 - FreeStyler® Maintenance Manual
P. 59

®
                       MAINTENANCE


                       Chapter 2 Preventative Maintenance


                       Pumping Station Float Valve Seal Replacement Kit #105884


                          Positioning the Float Valve for Operation
                          For optimum closing force and best operation of the Float Valve it is suggested that the Float Arm Assembly be set to a
                          45° or slightly greater angle. The Float Valve will not operate properly with the arm at a 90° angle.



                                            Optimum
                                            Working
                                            Range





                                      45°







                          When properly set, the Float valve should look as shown below




















                          If  the  Down-Tube  extends  below  the  surface  of  the  liquid,  the  Float  Valve  may  become  air  bound  and  not  close
                          properly. A small drilled hole (approximately 1/8”) has been drilled in the lower neck of the valve body, above the
                          thread to allow air to escape.













                                               1/8” drilled hole






                       1MANUL222               Belanger, Inc.® * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681                   2-31