KL2: 1063 PROGRAMMING AND OPERATION
Chapter 4 Operator Interface/Advanced Configuration
Setup / Advanced Configuration
Screen Key
The following selections move you to the corresponding
screen:
· APPLICATION CONFIGURATION
· OUTPUT NAMING
The factory password for this level is 4444. This password indicates security level 4.
ENABLED = ICS CLEAN CYCLE: This toggles between ENABLED and DISABLED. When ENABLED, a small
amount of water will evacuate the chemical from the main orifices or Presoak Injectors when the machine is not in
use. Do not ENABLE this feature if the chemical pumps (SDM) are used instead of injectors (ICS).
B/F CLAMP PRESSURE: Adjusts from 1 – 4. 4 is the strongest clamping pressure. 1 is the weakest clamping
pressure. Clamping pressure is how strong the butterfly arms close together. The gearbox can lock if the clamping
pressure is too strong.
Enter pumps via [ENTER OPERATION 1 / ENTER OPERATION 3]: Select which Entrance Operation will control
the 25HP pump.
Note: Output naming and application configuration must be modified to operate SDM
(Solution Discharge Module) instead of ICS (Injection Chemical System)
Chemical Delivery System, if applicable.