Page 104 - 2018 National Home Improvement
P. 104
2018 National Home Improvement Estimator, All Rights Reserved Page 84
Fiberglass Insulation
Kraft-faced fiberglass roll insulation. Stapled between studs or joists. Coverage includes framing
area.
R-11, 15" x 70'6" x 3-1/2" thick BC@.010 SF 0.42 0.40 0.83
R-11, 23" x 70'6" x 3-1/2" thick BC@.009 SF 0.42 0.36 0.79
R-13, 15" x 32' x 3-1/2" thick BC@.010 SF 0.42 0.40 0.83
R-19, 15" x 39' x 6-1/4" thick BC@.010 SF 0.60 0.40 1.00
R-19, 23" x 39' x 6-1/4" thick BC@.009 SF 0.64 0.36 1.00
Unfaced fiberglass roll insulation. Laid between ceiling joists. Coverage includes framing area.
R-6.7, 15" x 48" x 2" thick handy roll BC@.005 SF 1.06 0.20 1.26
R-19, 15" x 39' x 6-1/4" thick BC@.005 SF 0.65 0.20 0.85
R-19, 23" x 39' x 6-1/4" thick BC@.005 SF 0.56 0.20 0.76
R-25, 23" x 17' x 8" thick BC@.005 SF 0.77 0.20 0.97
R-25, 15" x 18' x 8" thick BC@.005 SF 0.77 0.20 0.97
R-30, 15" x 25' x 9-1/2" thick BC@.005 SF 0.76 0.20 0.96
R-30, 23" x 25' x 9-1/2" thick BC@.005 SF 0.76 0.20 0.96
Add for rolls in floor joists above a crawl space BC@.008 SF 0.08 0.32 0.40
Kraft-faced fiberglass batt insulation. Stapled between studs and joists. 16" widths and 24" widths
are laid over ceiling joists.
R-11, 15" x 93" x 3" thick BC@.012 SF 0.47 0.48 0.96
R-13, 15" x 93" x 3-1/2" thick BC@.012 SF 0.46 0.48 0.95
R-13, 23" x 93" x 3-1/2" thick BC@.013 SF 0.60 0.52 1.12
R-15, 15" x 93" x 6-1/4" thick BC@.009 SF 0.60 0.36 0.96
R-19, 15" x 93" x 6-1/4" thick BC@.009 SF 0.61 0.36 0.97
R-19, 23" x 93" x 6-1/4" thick BC@.013 SF 0.61 0.52 1.13
R-30, 16" x 48" x 10" thick BC@.005 SF 0.92 0.20 1.12
R-30, 24" x 48" x 10" thick BC@.005 SF 0.91 0.20 1.11
R-38, 16" x 48" x 12-1/2" thick BC@.007 SF 1.13 0.28 1.41
R-38, 24" x 48" x 12-1/2" thick BC@.005 SF 0.98 0.20 1.18
Unfaced fiberglass batt insulation. Fit between studs and joists. 16" and 24" widths are laid over
ceiling joists. Coverage includes framing area.
R-11, 15" x 94" x 3-1/2" thick BC@.007 SF 0.38 0.28 0.67
R-11, 16" x 96" x 3-1/2" thick BC@.006 SF 0.41 0.24 0.66
R-13, 15" x 93" x 3-1/2" thick BC@.007 SF 0.46 0.28 0.75
R-19, 15" x 93" x 6-1/4" thick BC@.007 SF 0.60 0.28 0.88
R-19, 23" x 93" x 6-1/4" thick BC@.006 SF 0.60 0.24 0.84
R-21, 15" x 93" x 5-1/2" thick BC@.007 SF 0.78 0.28 1.06
R-21, 23" x 93" x 5-1/2" thick BC@.006 SF 0.78 0.24 1.02
R-30, 16" x 48" x 9-1/2" thick BC@.005 SF 0.96 0.20 1.16
R-30, 16" x 48" x 10-1/4" thick BC@.005 SF 0.98 0.20 1.18
R-30, 24" x 48" x 9-1/2" thick BC@.005 SF 0.94 0.20 1.14
R-30, 24" x 48" x 10-1/4" thick BC@.005 SF 0.93 0.20 1.13
R-38, 16" x 48" x 13" thick BC@.007 SF 1.21 0.28 1.49
R-38, 24" x 48" x 13" thick BC@.007 SF 1.20 0.28 1.48
Add for batts in floor joists above a crawl space BC@.008 SF 0.06 0.32 0.38