Page 725 - Wurth Total Catalogue
P. 725

evapo  mat instructions
                  ®


        1. Evapo  – ‘Clean’ – application/ process.
                ®
             NB. - Prior to the application, check the contamination degree of the pollen/activated carbon filter and replace, if required. The work steps
          described refer to a vehicle A/C system with automatic climate control. When disinfecting other A/C systems proceed in a comparable
          manner.
                      ®
        •   Place the ‘EVAPO MAT’ directly on the vehicle floor area, ideally on the front passenger side.
        •   Attach the application hose to the blower connection neck and point it toward the intake air openings of the recirculating air inlet under the
          dash (usually near the bottom of the glove box).
        •  Start the vehicle and adjust the A/C system as follows
             (1)Auto climate control to ‘OFF’ (2) Economy mode to ‘ON’ (3) Temperature selection to the lowest setting – ‘LOW – (4) Recirculation mode
          to ‘ON’ – (5) Ventilation fan to the lowest setting (6) Switch for direction of air flow to ‘UP’ and open all air outlets on the dashboard (7)
          Switch on the ‘EVAPO MAT’ and check if the active ingredient mist is being drawn in (8) leave the vehicle and shut all windows and doors.  air-Con
                         ®
             After about twenty minutes all of the fluid will have been expelled. The evaporator cell switches off automatically, however the fan of the
          ‘EVAPO MAT’ will continue to run. After treatment, open all doors and windows and allow the vehicle interior to air out for ten minutes.
                ®
        2.  Evapo  – ‘Fresh’ – application/process.
                ®
        •   Place the ‘EVAPO MAT’ (without the application hose) in the floor area of the passenger side of the vehicle and switch on.
                      ®
        •   Leave the vehicle ensuring all doors and windows are closed.                                          Exhaust
        •   The fluid will have been expelled after 15 to 20 minutes. The evaporator cell switches off automatically, however the fan of the ‘EVAPO MAT’
                                                                                                      ®
          will continue to run.
        •   Open all doors and windows and allow the vehicle to air out for ten minutes.


        3.  Continuing problems & Their Solutions.                                                                Cooling
        When continuing unpleasant smells remain after initial treatment.
        •   The pollen/activated carbon filter of the A/C system could be heavily contaminated.
           -   Replace pollen/activated carbon filter.
        •   Heavy germ and bacteria deposits on the evaporator of the A/C system
           -    Rinse the evaporator above the condensation water run off.
           -    Afterwards, repeat the disinfection with EVAPO CLEAN.                                             Steering
                                           ®
           -    If the deposits cannot be removed then the evaporator should be replaced.
        •   Heavy contamination of the upholstery and seats caused by e.g., fluid leakage.
           -     Treat upholstery and carpet with Interior Cleaner (Article No. 0893 033).
           -    Afterwards, carry out an additional cleaning process with EVAPO FRESH.
                                                        ®
           -    Remove heavily soiled foot mats and plastic covered seats and clean with a  high pressure cleaner.
        4. Wurth Equipment Maintenance and Cleaning.                                                              Trans
        As with any equipment, regular maintenance is important for ongoing, optimum performance.
        -   Ensure the EVAPO MAT is disconnected from the power supply unit.
                       ®
        -  Remove the application hose.
        -   Remove the active ingredient canister from its receptacle.
        -   Fill approx.100ml of water into the can receptacle, lightly shake the unit and empty afterwards.      Intake
        -   Protect the on/off switch, intake air opening and connection socket from water splashes.
        -   Do not clean plastic parts and housing with solution or other aggressive substances.


                                                                                                                  Fuel






      AUS. pub. 01/14 ©                                                                                           oil





                                                          08 0581
   720   721   722   723   724   725   726   727   728   729   730