DI - 248 Diagnosis - Diagnosis-fault diagnosis of electronic and electrical parts
3. Check the left front fog lamp ground circuit
a. Ignition switch:LOCK.
b. Disconnect the connector B001 of left front fog lamp
c. Take a multimeter to measure resistance between No. 1
terminal of left front fog lamp connetor B0001 and
grounding.
Standard resistance:
Multimeter connecting terminal Standard value
B001(1)-grounding About 0Ω
Is the test result ok?
Yes> retest the above steps
NO>repair or replace the open harness