Page 337 - Foton Workshop Manual - Auman EST-M
P. 337
Diagnosis - Diagnosis-fault diagnosis of electronic and electrical parts DI - 283
IN
c. The positive and negative poles of bulb are connected to
the positive and negative poles of battery respectively.
Check if the bulb can be on. DI
EG
TR
Check if the result is ok? AX
Yes>go to Step 4.
No > replace with same size of bulb or check the earth circuit of reversing lamp. FR
4. Check the reverse lamp switch
a. Ignition switch: LOCK. ST
b. Disconnect the connector F015 of reverse lamp switch.
c. Place the shift controlling rod at the “reverse gear” position. BR
d. Measure the conduction between No.1 and 2 terminals of
reverse lamp switch F015 with a multimeter at its resistance BW
position.
Multimeter connecting terminal Standard value EL
F015(1)-F015(2) Conduction
Check if the result is ok?
Yes>go to Step 5.
NO>replace the reverse lamp switch.
DI-283